fix: xiaomi.derh.lite temperature precision
Add value-range step of 0.1 for dehumidifier temperature property to preserve decimal precision.
The xiaomi.derh.lite dehumidifier was reporting temperature as integer instead of float due to the default value-range step of 1. This fix changes the step to 0.1 to allow one decimal place precision (e.g., 22.5°C instead of 23°C).
Similar to the fix for cgllc.airm.cgd1st air monitor in commit 580ff87.
This commit is contained in:
parent
7abc20dcb5
commit
bb08c668cc
@ -92,6 +92,12 @@ urn:miot-spec-v2:device:air-purifier:0000A007:zhimi-ua1a:2: urn:miot-spec-v2:dev
|
|||||||
urn:miot-spec-v2:device:air-purifier:0000A007:zhimi-ua1a:3:
|
urn:miot-spec-v2:device:air-purifier:0000A007:zhimi-ua1a:3:
|
||||||
prop.3.5:
|
prop.3.5:
|
||||||
expr: (src_value*6)
|
expr: (src_value*6)
|
||||||
|
urn:miot-spec-v2:device:dehumidifier:0000A02D:xiaomi-lite:1:
|
||||||
|
prop.3.2:
|
||||||
|
value-range:
|
||||||
|
- -30
|
||||||
|
- 100
|
||||||
|
- 0.1
|
||||||
urn:miot-spec-v2:device:airer:0000A00D:hyd-lyjpro:1:
|
urn:miot-spec-v2:device:airer:0000A00D:hyd-lyjpro:1:
|
||||||
prop.2.3:
|
prop.2.3:
|
||||||
name: current-position-a
|
name: current-position-a
|
||||||
|
|||||||